4WE6L6X/EG24N9K4
Solenoid directional valve
- Material number / MPN
- R900901751
- Nominal size
- NG6
- Main ports / positions
- 4 ports / 3 positions
- Supply voltage
- 24 V DC (G24)

Request current product and nameplate photographs to confirm the exact supplied configuration.
Rexroth 4WE10L5X/EG24N9K4/M, material number R901278776, is an NG10 direct-operated 4/3 solenoid directional spool valve. It uses 24 V DC actuation, K4 electrical connections and NBR seals. Original new product; request current pricing.
Send your complete model code, quantity and destination. Price, condition, availability and delivery are confirmed in the quotation.
The Rexroth 4WE10L5X/EG24N9K4/M identifies an NG10, component-series 5X directional valve with spool symbol L. This catalog configuration uses two solenoids with spring centering. Provide the full nameplate and circuit requirements so the supplied unit can be confirmed.
The L center connects A to T while keeping P and B blocked. Match the actuator line on port A to the required rest-state return path. This differs from the J float center, which connects both A and B to T. Confirm the manifold port assignments, tank backpressure and actuator behavior before selecting this size 10 configuration.
4WE10 denotes a four-port solenoid-operated directional spool valve, size 10. L identifies the hydraulic symbol and 5X the component-series family. The spring-return or spring-centered arrangement applies. E after the slash identifies the high-power wet-pin solenoid with detachable coil. G24 is 24 V DC, N9 is the concealed manual override, and K4 is the individual electrical connection. The /M suffix specifies NBR seals; it is separate from the spool symbol.
| Brand | Rexroth |
|---|---|
| Condition | New |
| Catalog type code | 4WE10L5X/EG24N9K4/M |
| Material number / MPN | R901278776 |
| Valve type | Direct-operated solenoid directional spool valve |
| Nominal size | NG10 |
| Component series | 5X |
| Main ports / positions | 4 ports / 3 positions |
| Spool symbol | L |
| Solenoids | 2 |
| Return / holding arrangement | Spring-centered |
| Center / de-energized behavior | A connected to T; P and B blocked at center. |
| Supply voltage | 24 V DC (G24) |
| Electrical connection | K4; 3-pole (2 + PE), EN 175301-803; mating connector separate |
| Manual override | N9; concealed |
| Mounting pattern | ISO 4401-05-04-0-05 |
| Seals | NBR (/M) |
| Maximum P, A and B pressure | 350 bar; operating envelope applies |
| Maximum T-port pressure | 210 bar for DC version; manual override limit differs |
| Series DC flow ceiling | 160 L/min; series reference only, not a guaranteed flow rating for this spool |
Catalog pressure limits are 350 bar at P, A and B, and 210 bar at T for the DC version. N9 manual override operation is limited to a tank pressure of 50 bar and has no assigned safety function. Select the operating point using the actual flow path, pressure and fluid conditions.
The standard NG10 DC series has a catalog flow ceiling of 160 L/min. This is not a rated flow at every pressure for 4WE10L5X/EG24N9K4/M. Verify the exact spool performance curves, return pressure and pressure drop for the required flow. The maximum pressure and series flow ceiling are not a simultaneous operating guarantee.
No. L connects only A to T while P and B are blocked. J connects both A and B to T and blocks P. Match the port assignments and the required actuator behavior before ordering.
K4 specifies the valve electrical interface. Mating connectors are ordered separately; confirm plugs, subplate, mounting screws and other accessories in the quotation.
The standard NG10 DC series has a catalog flow ceiling of 160 L/min. This is not a rated flow at every pressure for 4WE10L5X/EG24N9K4/M. Verify the exact spool performance curves, return pressure and pressure drop for the required flow. The maximum pressure and series flow ceiling are not a simultaneous operating guarantee.
Send the full identification, quantity, destination, operating requirements and desired supply condition. Price, availability, delivery and warranty terms will be confirmed in the quotation.
Related models are for comparison. Spool function, mounting size and return behavior must be checked before selecting a replacement.

Solenoid directional valve

Solenoid directional valve

Solenoid directional valve
Send us the full model number or a photo of your nameplate.