4WE6Y6X/EG24N9K4
Solenoid directional valve
- Material number / MPN
- R900561276
- Nominal size
- NG6
- Main ports / positions
- 4 ports / 2 positions
- Supply voltage
- 24 V DC (G24)

Request current product and nameplate photographs to confirm the exact supplied configuration.
Rexroth 4WE10Y5X/EG24N9K4/M, material number R901278769, is an NG10 direct-operated 4/2 solenoid directional spool valve. It uses 24 V DC actuation, K4 electrical connections and NBR seals. Original new product; request current pricing.
Send your complete model code, quantity and destination. Price, condition, availability and delivery are confirmed in the quotation.
The Rexroth 4WE10Y5X/EG24N9K4/M identifies an NG10, component-series 5X directional valve with spool symbol Y. This catalog configuration uses one solenoid with spring return. Provide the full nameplate and circuit requirements so the supplied unit can be confirmed.
The Y configuration has a spring-return position a that connects P to B and A to T. When energized, position b connects P to A and B to T. This rest-state flow direction differs from the ordinary D spring-return configuration. Check which actuator line is connected to each work port and confirm the machine sequence together with the NG10 mounting pattern.
4WE10 denotes a four-port solenoid-operated directional spool valve, size 10. Y identifies the hydraulic symbol and 5X the component-series family. Y uses positions a and b, with spring return to a. E after the slash identifies the high-power wet-pin solenoid with detachable coil. G24 is 24 V DC, N9 is the concealed manual override, and K4 is the individual electrical connection. The /M suffix specifies NBR seals.
| Brand | Rexroth |
|---|---|
| Condition | New |
| Catalog type code | 4WE10Y5X/EG24N9K4/M |
| Material number / MPN | R901278769 |
| Valve type | Direct-operated solenoid directional spool valve |
| Nominal size | NG10 |
| Component series | 5X |
| Main ports / positions | 4 ports / 2 positions |
| Spool symbol | Y |
| Solenoids | 1 |
| Return / holding arrangement | Spring return |
| Center / de-energized behavior | P connected to B; A connected to T in spring-return position a. |
| Energized behavior | Position b: P connected to A; B connected to T. |
| Supply voltage | 24 V DC (G24) |
| Electrical connection | K4; 3-pole (2 + PE), EN 175301-803; mating connector separate |
| Manual override | N9; concealed |
| Mounting pattern | ISO 4401-05-04-0-05 |
| Seals | NBR (/M) |
| Maximum P, A and B pressure | 350 bar; operating envelope applies |
| Maximum T-port pressure | 210 bar for DC version; manual override limit differs |
| Series DC flow ceiling | 160 L/min; series reference only, not a guaranteed flow rating for this spool |
Catalog pressure limits are 350 bar at P, A and B, and 210 bar at T for the DC version. N9 manual override operation is limited to a tank pressure of 50 bar and has no assigned safety function. Select the operating point using the actual flow path, pressure and fluid conditions.
The standard NG10 DC series has a catalog flow ceiling of 160 L/min. This is not a rated flow at every pressure for 4WE10Y5X/EG24N9K4/M. Verify the exact spool performance curves, return pressure and pressure drop for the required flow. The maximum pressure and series flow ceiling are not a simultaneous operating guarantee.
The spring selects position a, connecting P to B and A to T. Energizing the solenoid selects position b, connecting P to A and B to T. Confirm the required actuator direction and port assignments; there is no neutral center position.
K4 specifies the valve electrical interface. Mating connectors are ordered separately; confirm plugs, subplate, mounting screws and other accessories in the quotation.
The standard NG10 DC series has a catalog flow ceiling of 160 L/min. This is not a rated flow at every pressure for 4WE10Y5X/EG24N9K4/M. Verify the exact spool performance curves, return pressure and pressure drop for the required flow. The maximum pressure and series flow ceiling are not a simultaneous operating guarantee.
Send the full identification, quantity, destination, operating requirements and desired supply condition. Price, availability, delivery and warranty terms will be confirmed in the quotation.
Related models are for comparison. Spool function, mounting size and return behavior must be checked before selecting a replacement.

Solenoid directional valve

Solenoid directional valve

Solenoid directional valve
Send us the full model number or a photo of your nameplate.