Manufacturer reference information · Confirm the exact model and configuration before ordering.
Hydraulic & Pneumatic Components
AI-generated Rexroth A10VSO series appearance reference for the A10VSO140LA9DS inquiry page; exact configuration is not verified
AI-generated series appearance reference. Actual supply is subject to the confirmed configuration.

This AI-generated image is based on Rexroth A10VSO series reference photographs. It is not a photograph of a stock unit and does not verify this model’s exact configuration. Request current product and nameplate photographs with your quotation.

Rexroth / Hydraulic Pumps

Rexroth A10VSO140LA9DS Variable Axial Piston Pump

Rexroth A10VSO140LA9DS, Series 32: a size 140 variable axial piston pump with pressure, flow and power control for open-circuit hydraulics. Request a quote with your complete model code.

Base model: A10VSO140LA9DS
Reference series
32
Nominal size
NG 140
Control
LA9DS — Pressure, flow and power control

Send your complete model code, quantity and destination. Price, condition, availability and delivery are confirmed in the quotation.

The Rexroth A10VSO140LA9DS is a variable axial piston pump for open-circuit hydraulic systems. This page covers the size 140 LA9DS model with Series 32 catalog reference data. DENGFENG accepts inquiries for original Rexroth products and confirms the exact configuration, condition and availability for each quotation.

Reviewing size 140 LA9DS at the operating speed

An A10VSO140LA9DS inquiry should state the motor rating, drive speed and desired power characteristic. Include pressure cut-off, flow demand and the load-sensing unloading circuit. Confirm the exact controller setting and mechanical suffix before treating a nearby LA category as a replacement option.

Key features

  • Size 140 with LA9DS pressure, flow and power control
  • Series 32 catalog reference
  • Maximum geometric displacement: 140 cm³/rev
  • Nominal pressure: 280 bar (catalog reference)
  • Original Rexroth product inquiry; exact unit confirmed in the quotation

Controller function

LA9DS combines power control, pressure cut-off and flow control. LA9 identifies a power-control start range above 240 bar. Specify the required power characteristic and operating speed, and confirm the load-sensing unloading arrangement. The category is not a fixed motor-power setting.

Model and configuration

Reference values apply to Series 32, with rotary group version E as covered by the reviewed technical table. Confirm the full suffix, applicable fluid and supplied version before applying these values to an individual unit.

BrandRexroth
Base modelA10VSO140LA9DS
Reference series32
Pump typeVariable axial piston pump, swashplate design
CircuitOpen circuit
Nominal sizeNG 140
Maximum geometric displacement140 cm³/rev
ControlLA9DS — Pressure, flow and power control
Nominal pressure, catalog reference280 bar
Maximum pressure, catalog reference350 bar; applicable operating limits apply
Rotation, shaft, flange, seals and portsConfirm from the complete model code and unit documentation
Through drive and special optionsConfirm the complete suffix; no default configuration assumed
Power-control start categoryAbove 240 bar (LA9); confirm the required power characteristic at the drive speed

Maximum pressure is not a continuous-duty setting. Confirm the applicable operating limits for the exact supplied unit.

How to check the fit

  • Provide the operating speed and required power characteristic, then verify LA9DS and the complete installed code.
  • Compare the rotation, shaft, mounting flange, ports, seals and through-drive option with the installed unit.
  • Check the hydraulic circuit, operating conditions and exact unit specifications before ordering.

Request a quotation

  • Complete model code and Rexroth material number, if available
  • Readable pump and controller nameplate photographs
  • Quantity, destination country and required delivery date
  • Required flow, operating pressure, drive speed and hydraulic fluid
  • Required condition and any documentation requirements
  • Motor power, operating speed and required power-control characteristic
  • Load-sensing circuit and unloading arrangement
  • Required pressure cut-off and flow-control settings

Request a Quote for A10VSO140LA9DS

Frequently asked questions

Is A10VSO140LA9DS a complete ordering code?

No. It identifies a size and controller combination. Send the full nameplate code, including the series and all suffixes, so the exact configuration can be quoted.

Are price and stock shown on this page?

Price, condition, availability and delivery are confirmed individually after the complete model and quantity are reviewed.

Does LA9 specify a fixed motor power?

No. The category identifies the beginning-of-power-control range. Specify the required power characteristic with the operating speed and confirm the quoted factory setting.

Can a different LA category be substituted directly?

Confirm the required power characteristic at the drive speed, pressure cut-off, flow-control circuit and unloading arrangement. The LA category and complete pump configuration need to be reviewed before a replacement is specified.

Related Rexroth models

Related models are selection references. Interchangeability has not been established.

All Rexroth pumps ↗

Can't Find the Part You Need?

Send us the full model number or a photo of your nameplate.

Send an Inquiry